Used Heat Exchangers


 

Used High Pressure Heater, 10th stage, LSU is a two pass feedwater heater     Used Cross Over Heater, LSU is a two- pass feedwater heater designed to

designed to heat 873,000 lb/hr of water from 311deg f to 365 deg f when          heat 873,400 lb/hr of water from 365 deg F to 458 deg F when supplied with

 supplied with 39,100 lb/hr of extraction steam at 191psia and 785 deg f             85,000 lb/hr of extraction steam from the cross over line at 519 PSIA and

and includes the drains from the cross over heater. The design pressure                747 deg F. The design pressure and temperature are 2600 PSI and 500

and temperature are 2600 psi and 450 deg f of the water side and 300 psi           deg F on the water side and 600 psig  and 800 deg F on the steam side.

and 850 deg f on the steam side. there is a 3,644 sq/ft condensing section and      Griscom-Russell  Thermal Engineering ,   Type 32-6- 259                                                

 a 466 sq/ft subcooling section, Griscom-Russell Yubu ,    Type 32-6-261                51231A rebiuld 8-5-96    512323A  In stalled1952 & 99-4401

  51446A Rebuild 5-31-96, 86-h-295-1 Install 1987 &  51448A                       Installed 2000

Installed 1953, Quanity= 3                                          

  

Used Low Intermediate Pressure Heater, is horizontal two-pass condensate               Used Deaerator Heater & Storage Tank, is a 14th stage heater with a

heater including a 2,259 sq/ft condensing section and a 186 sq/ft sub-cooling section.     deaerating capability of 0.005 cm3 of oxygen per liter at 900,000 lb/hr

This two-pass  condensate heater is designed to heat 675,000 lb/hr of water from          condensate flow and mounted on a boiler feed storage tank with approx.

178.3 deg F to 235.3 def F when supplied with 36,400 lb/hr extraction steam at            16,800 gallons of storage providing nine minutes of water flow to the boiler

25.8 psia and 380 deg F. Griscom- Russell, Type 34-6-179 SSU, Quanity =3            when operating at a capacity of  900,000 lb/hr steam flow. The deaerator is

                                                                                                                                   desighned to pass 873,400 lb/hr of feedwater to the boiler feedpump suction

                                                                                                                                    It is designed for 75 psi and fitted with four banks of stainless steel trays.